EC-40 cond

All features at a glance
• Display COND/TDS and
Temperature simultaneously
• Resolution: automatic scale
• Selectable cell constant allows
for use with 2 plate cell
• Automatic calibration 1 to 4 points
between 4 conductivity
standard values
• Manual-Calibration up to 1 points
(User defined)
• Large 2 color display with indication
of Calibration Standards
and measurement’s stability
• Instrument can be delivered
with a magnetic stirrer
• IP54 Protection
• 3 years instrument warranty
|
 |
|
|
EC-45 cond

additional for EC-45 cond
• Selectable cell constant allows for use
with 2 or 4 plate cell
• GLP and IQ-OQ manual available
• Automatic and manual compensation
of temperature with reference
value 15...30 °C
• Memory with re-call of last calibration
date and time and information
of cell constant
• CAL DUE: set of calibration frequency
for high quality of measurements
• Non-volatile memory holds up
to 1000 data points with date and time
in automatic (Data logger)
or manual printer
• 2 x USB ports to transfer data and
software PC-Link to download data
(included)
|
 |
|
Professional Conductivity Benchtop Meter EC-40 cond • EC-45 cond
The large color display easy on to read shows all information necessary information about measurement, calibration, standards, cell condition, GLP. Anyone can use this meter easily with its intuitive menu available in up to 8 languages in the EC-45 cond. Easy to learn.
Up to 4 calibration points with buffer recognition. Icon support for all calibration functions and advanced electrode diagnostics. Easy to calibrate.
All functions can be controlled in an intuitive and easy way. Both instruments can be delivered with a stirrer.
|
|
Technical data
Cond. Measuring range
Resolution cond
Relative accuracy
TDS Measuring range
TDS factor
Relative Accuracy
Temperature range
Accuracy/Resolution Temp.
Temperature compensation
Temperature calibration
Calibration points
Calibration standards recognized
Indication of cell condition
GLP
CALDUE
Memory
Inputs
Protection class
Power supply
Dimensions
Weight
|
EC-40 cond
0,00 - 200
Automatic scale
±0,5 % value reading
0,1 mg/l - 100 g/l
0.40...1.00
±0,5 % value reading
0 - 100
0,1/±0,2
Manual or automatic
Yes
1 bis 4
84, 1413 µS / 12.88,
111.8 mS, benutzerdef.
Yes
No
No
No
-
IP 54
AC/DC adapter
9 V, 300 mA
200 x 220 x 100
950 g
|
EC-45 cond
0,00 - 1000
Automatic scale
±0,5 % value reading
0,1 mg/l - 500 g/l
0.40...1.00
±0,5 % value reading
-20 - 200
0,1/±0,2
Manual or automatic
Yes
1 bis 4
84, 1413 µS / 12.88,
111.8 mS, benutzerdef.
Yes
Yes, date/time
Yes
1000 Data
2 x USB
IP 54
AC/DC adapter
9 V, 300 mA
200 x 220 x 100
950 g
|
|
Various sets are available:
EC-40 cond 0
Kit without cell, with standard solution 1413 µS and 12,88 mS,
cell holder and accessories
EC-40 cond 1
Kit included cell 2301T, standard solution 1413 µS and 12,88 mS,
cell holder and accessories
EC-40 cond 2
Kit without cell, with standard solution 1413 µS and 12,88 mS,
cell holder and accessories,
with magnetic stirrer
EC-40 cond 3
Kit included cell 2301T, standard solution 1413 µS and 12,88 mS,
cell holder and accessories,
with magnetic stirrer
EC-45 cond 0
Kit without conductivity cell, standard solution 1413 µS and 12,88 mS,
cell holder and accessories
EC-45 cond 1
Kit included conductivity cell Glass-Pt VPT80/1, standard solution 1413 µS and 12,88 mS,
cell holder, power supply and accessories
EC-45 cond 2
Kit without cell, with standard solution 1413 µS and 12,88 mS,
cell holder and accessories,
with magnetic stirrer
EC-45 cond 3
Kit included cell Glass-Pt VPT80/1, standard solution 1413 µS and 12,88 mS,
cell holder and accessories,
with magnetic stirrer
|
Downloads (PDF)
|
|
|
|

Catalog Elektrodes
and Accessories
|

Catalog Elektrochemistry
|
|

|
|