Heinkelstr. 4 

D-30827 Garbsen

info@phoenix-instrument.de

Tel. +49 5131 90 818 -30

Electrochemistry

DHS - The Digital Revolution


DHS, Digital High Sensor, is our new pH-sensor technology. These electrodes have an internal chip and stores all relevant calibration data, date of last calibration, slope, model and production batch. 


If you connect a DHS-electrode with an DHS instrument, all data will be transferred from the chip into the instrument and the user can start immediately with its measurements without any additional calibrations.  The new DHS-electrodes do not need an internal battery and can be connected by a normal BNC-connector. 


All instruments equipped with the new DHS technology can also be equipped with normal analog pH-electrodes. PH measurement was never easier. 

Digital High Sensor pH Electrode

All electrodes can be maintained and calibrated by one central person in the lab.


In use, every electrode will be allocated

to one pH-meter

Portable pH-Meter EC-21 pH and EC-26 pH


In the development of the new EC-21/EC-26 series, a particular focus was put on easy handling during daily routine.


The high-resolution color display guides the user intuitively through all measurement and calibration processes.

3 Years

Instrument Warranty

Additional for EC-26 pH


• GLP functions

• Data logger (automatic or manual) 

   1000 data records

• Connection to PC via micro-USB

• free DATA LINK +

• automatic brightness adjustment

• high-resolution colour display, adjustable brightness

• DHS function, automatic recognition of DHS and analogue sensors

• Display of pH/mV and temperature values

• automatic pH calibration up to 3 points

• automatic ORP 1-point calibration

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 57

• Supplied in a robust transport case with all accessories

Technical data


Meas. range

Resolution

Calibration points

Buffer resolution


Measuring range

Resolution

Temp. measuring range

Resolution / accuracy

GLP

Calibration alarm

Memory

Interface

IP-class

Dimension

Weight

EC-21 pH


0.00 … 14.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and

user defined

± 1,000 mV

1  mV

0,0 … 100 °C

0.1 / ± 0,5 °C

no

no

no

no

IP 57

185 x 85 x 45 mm

400 g

EC-26 pH


-2.00 … 16.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and

user defined

- 1,000 … 1,900 mV

0.1 / 1  mV

-10 - 110 °C

0.1 / ± 0.5 °C

yes

yes

1,000 data

Micro USB

IP 57

185 x 85 x 45 mm

400 g

Available Sets

EC-21-pH-0



EC-21-pH-1



EC-21-pH-5




EC-26-pH-0



EC-26-pH-1



EC-26-pH-5

Kit without pH electrode, with temperature sensor, cable S7/BNC, pH buffer solution, carrying case and accessories


Kit included pH electrode 201T, pH buffer solution, carrying case and accessories


Kit included pH electrode 201T-DHS, pH buffer solution, carrying case and accessories



Kit without pH electrode, with temperature sensor, cable S7/BNC, pH buffer solution, carrying case and accessories


Kit included pH electrode 201T, pH buffer solution, carrying case and accessories


Kit included pH electrode 201T-DHS, pH buffer solution, carrying case and accessories

Basic Benchtop pH-Meter EC-31 pH and EC-36 pH

• high-resolution color display, adjustable brightness

• DHS function, automatic recognition of DHS and analogue sensors

• Display of pH/mV and temperature values

• automatic pH calibration up to 3 points

• automatic ORP 1-point calibration

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 54

3 Years

Instrument Warranty

Additional for EC-36 pH


• GLP functions

• Data logger (automatic or manual) 1,000 data records

• Connection to PC via micro-USB

• free DATA LINK +

Technical data


Meas. range

Resolution

Calibration points

Buffer resolution


Measuring range

Resolution

Temp. measuring range

Resolution / accuracy

GLP

Calibration alarm

Memory

Interface

IP-class

Dimension

Weight

EC-31 pH


0.00 … 14.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and user defined

± 1,000 mV

1  mV

0.0 … 100 °C

0.1 / ± 0,5 °C

no

no

no

no

IP 54

170 x 145 x 60 mm

530 g

EC-36 pH


-2.00 … 16.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and user defined

- 1,000 … 1,900 mV

0.1 / 1  mV

-10 - 110 °C

0.1 / ± 0.5 °C

yes

yes

1.000 data

Micro USB

IP 54

170 x 145 x 60 mm

530 g

Available Sets

EC-31-pH-0



EC-31-pH-1


EC-31-pH-5



EC-36-pH-0



EC-36-pH-1


EC-36-pH-5

Kit without pH electrode, with temperature sensor, cable S7/BNC, 

pH buffer solution, electrode holder


Kit included pH electrode 201T, pH buffer solution, electrode holder


Kit included pH electrode 201T-DHS, pH buffer solution, electrode holder



Kit without pH electrode, with temperature sensor, cable S7/BNC, 

pH buffer Solution, electrode holder


Kit included pH electrode 201T, pH buffer solution, electrode holder


Kit included pH electrode 201T-DHS, pH buffer solution, electrode holder

Professional Benchtop pH Meter EC-45 pH

• Display pH/mV and Temperature parameters simultaneously

• Resolution: 0.001 pH

• Automatic Calibration up to 5 points with automatic buffer recognition 

• DHS-function, automatic recognition of DHS- and analog electrodes

• GLP and IQ-OQ manual available

• Large, colored graphic display

• Memory with re-call of last calibration date and time and information of electrode’s life 

• CAL DUE: set of calibration frequency for high quality of measurements

• Non-volatile memory holds up to 1,000 data points with date/ time in automatic (Data logger) or manual  

• External keypad

• 2 x USB ports and 1 x RS-232 interface to transfer data at PC or printer and for external keyboard 

• Instrument can be equipped with a magnetic stirrer 

• IP54 rated housing handles splashes

3 years

Instrument Warranty

EC-45 pH with electrode arm and optional stirrer

Technical data


Meas. range

Resolution

Buffer solution

Calibration points

Buffer recocnition

Measuring range

Resolution

Measuring range

Resolution

DHS Electrode

Buffer resolution

Timer

GLP

Interface

Display

IP-class

Power supply

Weight

Dimension

EC-45 pH


-2 … 20 pH

0,1 / 0,01 / 0,001 pH

1 … 5 / USA, NIST, DIN, user defined 

1 … 5

yes

± 2,000 mV

0.1 / 1 mV

-30.0 … 130.0 °C

± 0.1 °C

yes

1,000 data

yes

yes

2 x USB, RS-232

Colored graphic display

IP 54

Adapter 12 V DC 

1,050 g, without stirrer

165 x 195 x 68 mm

Available Sets

EC-45-pH-0



EC-45-pH-1

    



EC-45-pH-2



EC-45-pH-3




EC-45-pH-5    




EC-45-pH-6    





1001502

Kit without pH electrode, with cable S7/BNC, temperature probe NT55, DHS-function,

pH buffer solution pH 7 and pH 4, electrodes arm, keypad, power supply and accessories


Complete kit included pH electrode STANDARD, DHS-function, temperature probe NT55, S7/BNC 1 m cable, pH buffer solution pH 7 and pH 4, electrodes arm, power supply, keypad, accessories


Kit without pH electrode, with cable S7/BNC, temperature probe NT55, DHS-function, pH buffer solution pH 7 and pH 4, electrodes arm, power supply, keypad with magnetic stirrer 


Complete kit included pH electrode STANDARD, temperature probe NT55, S7/BNC 1 m cable, DHS-function, pH buffer solution pH 7 and pH 4, electrodes arm, keypad, power supply, with magnetic stirrer


Complete kit included pH electrode STANDARD-DHS, DHS-function, temperature probe NT55, S7/BNC 1 m cable, pH buffer solution, electrodes arm, power supply, keypad and accessories


Complete kit included pH electrode STANDARD-DHS, DHS-function, temperature probe NT55, S7/BNC 1 m cable, pH buffer solution, electrodes arm, power supply, keypad, accessories, with magnetic stirrer



Printer for EC-35 and EC-45

 Printer 1001502

Portable Conductivity Meter EC-21 cond and EC-26 cond


In the development of the new EC-21/EC-26 series, particular emphasis was put on easy handling during daily routine. 

The high-resolution color display guides the user intuitively through all measurement and calibration processes.

Additional for EC-26 pH


• GLP functions

• Data logger (automatic or manual)

    1000 data records

• Connection to PC via micro-USB

• free DATA LINK +

• automatic brightness adjustment

3 years

Instrument Warranty

• high-resolution colour display, adjustable brightness

• DHS function, automatic recognition of DHS and analogue sensors

• Display of Conductivity/TDS and temperature values

• automatic Conductivity calibration up to 5 points

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 57

• Supplied in a robust transport case with all accessories

Technical data


Meas. range conductivity 

Accuracy

Calibration points

Selectable cell constant

Temp. range

Resolution / accuracy

TDS meas. range

GLP

Calibration alarm

Memory

Interface

IP class

Dimension

Weight

EC-21 cond


0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

0,0 … 100 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

no

no

no

no

IP 57

185 x 85 x 45 mm

400 g

EC-26 cond


0,00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

-10 … 110 °C 

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

yes

yes

1,000 data

Micro USB

IP 57

185 x 85 x 45 mm

400 g

Available Sets

EC-21-cond-0


EC-21-cond-1



EC-26-cond-0



EC-26-cond-1

Kit without cell, with standard calibration solutions, carrying case and accessories 


Complete kit include cond. Cell 2301T with ATC, cable length 1m and BNC plug, 

standard calibration solutions, carrying case and accessories


Kit without cell, with standard calibration solutions, power supply, software PC-Link,

USB cable, carrying case with accessories 


Complete kit include cond. Cell 2301T with ATC, cable length 1m and BNC plug, 

Standard calibration solutions, power supply, software PC-Link to download data, USB cable, carrying case with accessories.

Basic Benchtop Conductivity EC-31 cond and EC-36 cond

• high-resolution colour display, adjustable brightness

• Display of Conductivity/TDS and temperature values

• automatic conductivity calibration up to 5 points

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 54

3 years

Instrument Warranty

Additional for EC-36 cond


• GLP functions

• Data logger (automatic or manual) 1,000 data records

• Connection to PC via micro-USB

• free DATA LINK +

Technical data


Meas. range conductivity 

Accuracy

Calibration points

Selectable cell constant

Temp. range

Resolution / accuracy

TDS meas. range

GLP

Calibration alarm

Memory

Interface

IP class

Dimension

Weight

EC-31 cond


0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

0.0 … 100 °C

0.1 / ± 0,5 °C

0.1 mg/l … 200 g/l

no

no

no

no

IP 54

185 x 85 x 45 mm

530 g

EC-36 cond


0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

-10 – 110 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

yes

yes

1,000 data

Micro USB

IP 54

185 x 85 x 45 mm

530 g

Available Sets

EC-31-cond-0


EC-31-cond-1



EC-36-cond-0



EC-36-cond-1

Kit without cell, with standard calibration solutions, cell holder and accessories


Complete kit include cond. Cell 2301T with ATC, cable length 1m and BNC plug, standard calibration solutions, cell holder and accessories


Kit without cell, with standard calibration solutions, power supply,

software PC-Link, USB cable, cell holder and accessories


Complete kit include cond. Cell 2301T wit ATC, cable length 1m and BNC plug, Standard calibration solutions, power supply, software PC-Link, USB cable,

cell holder and accessories

Professional Conductivity Benchtop Meter EC-45 cond

• Display COND/TDS, Salinity and Temperature simultaneously

• Resolution: automatic scale

• GLP-conform

• external keypad

• Selectable cell constant allows for use with 2 plate cell

• Automatic calibration 1 to 4 points between 4 conductivity standard values

• Manual-Calibration up to 1 points (User defined)

• Large colored graphic display with indication of Calibration Standards and measurement’s stability

• Automatic and manual compensation of temperature with reference value 15 … 30 °C

• Memory with re-call of last calibration date and time and information of cell constant

• CAL DUE: set of calibration frequency for high quality of measurements

• Non-volatile memory holds up to 1,000 data points with date and time Data logger

• 2x USB ports and 1 x RS-232 interface to transfer data and software PC-Link to download data 

• Instrument can be delivered with a magnetic stirrer 

• IP54 Protection

3 years

Instrument Warranty

EC-45 cond with stand and optional stirrer

Technical data


Mesuaring range (cond)


Resolution (cond)

Calibration Standards

Calibration points

Selectable cell type constant

Reference temperature

Temp. compensation

Measuring range

Resolution

TDS-measuring range

TDS-Faktor

Salinity

Resistivity

Memory

Timer

GLP

Interfaces

Display

Ip protection

Power supply

Weight

Dimension

EC-45 cond


0.00 - 20.00 - 200.0 - 2,000 μS

2.00 - 20.00 - 200.0 - 1,000 mS

Automatic full scale

84; 1413 μS; 12.88; 111.8 mS;  user

1 … 4

0.55 (4 rin 0.1 – 1 – 10)

15 … 30 °C

0.00 … 100.0 °C

-30.0 … 130.0  °C

± 0.5  °C

0 … 500 g/l

0.40 … 1.00

0.01 … 100 ppt

1 … 10 MΩ

1,000 data

yes

yes

2 x USB, RS-232

Color graphic display

IP 54

Adapter 12 V DC 

1.050 g, without stirrer

165 x 195 x 68 mm

Avaliable Sets

EC-45 cond 0



EC-45 cond 1



EC-45 cond 2



EC-45 cond 3

Kit without conductivity cell, standard solution 1413 µS and 12,88 mS, cell holder and accessories


Kit included conductivity cell Glass-Pt VPT80/1, standard solution 1413 µS and 12,88 mS, cell holder, power supply and accessories


Kit without, with standard solution 1413 µS and 12,88 mS, cell holder and accessories,

with magnetic stirrer 


Kit included cell Glass-Pt VPT80/1, standard solution 1413 µS and 12,88 mS, cell holder

and accessories, with magnetic stirrer

Portable Multiparameter Meter EC-21 multi and EC-26 multi

3 years

Instrument Warranty

Additional for EC-26 multi


• GLP functions

• Data logger (automatic or manual)

    1000 data records

• Connection to PC via micro-USB

• free DATA LINK +

• automatic brightness adjustment

• high-resolution colour display, adjustable brightness

• Display of pH/mV, Conductivity/TDS, temperature values

• automatic Conductivity calibration up to 5 points

• automatic pH calibration up to 3 points

• automatic ORP 1-point calibration

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 57

• Supplied in a robust transport case with all accessories

Technical data


Measuring range

Accuracy

Calibration points

Buffer resolution


Measuring range cond

Accuracy cond

Calibration points

Selectable cell constant

Temperature meas. range

Resolution / accuracy

TDS meas. range

GLP

Calibration alarm

Memory

Interface

IP-class

Dimension

Weight

EC-21 multi


0.00 … 14.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and

user defined

0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

0.0 … 100 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

no

no

no

no

IP 54

185 x 85 x 45 mm

530 g

EC-26 multi


0.00 … 14.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and

user defined

0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

-10 … 110 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

yes

yes

1,000 data

Micro USB

IP 54

185 x 85 x 45 mm

530 g

Available  Sets

EC-21-multi-0



EC-21-multi-1



EC-21-multi-5 



EC-26-multi-0



EC-26-multi-1




EC-26-multi-5

Kit without pH-electrode, with conuctivity cell 2301T, with standard calibration solutions, Temperature sensor, cable S7/BNC, carrying case with accessories 


Complete kit include pH electrode 201T and cond. Cell 2301T with ATC, both cable length 1m and BNC plug, standard calibration solutions, carrying case and accessories


Kit included pH electrode 201T-DHS, pH buffer solution, carrying case and accessories



Kit without pH-electrode and cell, standard calibration solutions, power supply, software PC-Link, USB cable, carrying case with accessories 


Kit include pH-electrode 201T and cell 2301T with ATC, cable length 1m and BNC plug, standard cal. solutions, power supply, software PC-Link , USB- cable, carrying case with accessories


Kit included pH electrode 201T-DHS, pH buffer solution, carrying case and accessories

Basic Benchtop Multi Meter EC-31 multi and EC-36 multi

• high-resolution colour display, adjustable brightness

• Display of pH/mV, Conductivity/TDS and temperature values

• automatic Conductivity calibration up to 5 points

• automatic pH calibration up to 3 points

• automatic ORP 1-point calibration

• selectable stability parameter (low-medium-high)

• automatic and manual temperature compensation

• Protection class IP 54

3 years

Instrument Warranty

Additional for EC-36 cond


• GLP functions

• Data logger (automatic or manual) 1000 data records

• Connection to PC via micro-USB

• free DATA LINK +

Technical data


Measuring range

Accuracy

Calibration points

Buffer resolution


Measuring range cond

Accuracy cond

Calibration points

Selectable cell constant

Temperature meas. range

Resolution / accuracy

TDS meas. range

GLP

Calibration alarm

Memory

Interface

IP-class

Dimension

Weight

EC-31 multi


0.00 … 14.00 pH

0.1 / 0,01 pH

1 … 3

USA, NIST and 

user defined

0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

0.0 … 100 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

no

no

no

no

IP 54

185 x 85 x 45 mm

530 g

EC-36  multi


0.00 … 16.00 pH

0.1 / 0.01 pH

1 … 3

USA, NIST and

user defined

0.00 … 200 mS

0.1/1 μS; 0.01/0.1 mS

1 … 5

0.1 – 1 – 10 cm⁻¹

-10 … 110 °C

0.1 / ± 0.5 °C

0.1 mg/l … 200 g/l

yes

yes

1,000 data

Micro USB

IP 54

185 x 85 x 45 mm

530 g

Available Sets

EC-31-multi-0



EC-31-multi-1




EC-31-multi-5




EC-36-multi-0



EC-36-multi-1




EC-36-multi-5

Kit without pH-electrode, with conuctivity cell 2301T, with standard calibration solutions, Temperature sensor, cable S7/BNC, pH buffer solutions, electrode holder


Complete kit include pH electrode 201T and cond. Cell 2301T with ATC, both cable length 1m and BNC plug, standard calibration solutions, pH buffer solutions, 

electrode holder


Complete kit include pH electrode 201T-DHS and cond. Cell 2301T with ATC,

both cable length 1m and BNC plug, standard calibration solutions, 

pH buffer solutions, electrode holder


Kit without pH-electrode, with conuctivity cell 2301T, with standard calibration solutions, Temperature sensor, cable S7/BNC, pH buffer solutions, electrode holder


Complete kit include pH electrode 201T and cond. Cell 2301T with ATC, both cable length 1m and BNC plug, standard calibration solutions, pH buffer solutions,

electrode holder


Complete kit include pH electrode 201T-DHS and cond. Cell 2301T with ATC, 

both cable length 1m and BNC plug, standard calibration solutions, 

pH buffer solutions, electrode holde

Professional Benchtop Multiparameter Meter EC-45 multi

• Display pH/mV,COND/TDS, Salinity and Temperature simultaneously

• Resolution: 0.1-0.001 pH; Auto range for Cold

• GLP-conform 

• Selectable cell constant allows for use with 2 plate cell

• Large colored graphic display with indication of Calibration Buffers and measurement’s stability

• Indication stability of the measurement with icon

• Memory with re-call of last calibration date and time and information of electrode’s life 

• CAL DUE: set of calibration frequency for high quality of measurements

• Stability Parameter (Low-Med-High) for high accuracy measurement

• Non-volatile memory holds up to 1,000 data points with date and time

    in automatic (Data logger) or manual

• 2x USB ports to transfer data at PC or printer and for external keyboard 

• Software PC-Link to download data (included)

• external keypad

• Intrument can be delivered with magnetic stirrer  

• IP54 protection

3 years

Instrument Warranty

EC-45 multi with stand and optional stirrer

Technical data


Measuring range

Accuracy

Buffer

Calibration points

Buffer recognition

Meas. range

Accuracy

Meas. range

Accuracy

DHS-Electrode

Meas. range cond


Accuracy cond

Buffer

Calibration points

Selectable cell constant

Reference temperature

Temp. compensation

TDS-Meas. range  

TDS-Factor

Salinity

Resistivity

Speicher

Timer

GLP

Interface

Display

IP-class

Power supply

Dimension

Weight

EC-45 multi


-2 … 20 pH

0.1 / 0.01 / 0.001 pH

1 … 5 /USA, NIST, DIN, User

1 … 5

yes

± 2,000 mV

0.1 / 1 mV

-20.0 … 120,0 °C

± 0.5 °C

yes

0.00 - 20.00 - 200.0 - 2000 μS /

2.00 - 20.00 - 200.0 - 1000 mS

Automatic full scale 

84, 1413 μS, 12.88, 111.8 mS, User

1…5

0,1 – 1 – 10 cm-1

15 … 30 °C

0.00 … 10.00 % °C

0 … 500 g/l

0.40 … 1.00

0.01 … 100 ppt

02 … 20 MΩ

1.000 data

yes

yes

2 x USB, RS-232

Color display

IP 54

Adapter 12 V DC 

165 x 195 x 68

1.050 g without stirrer

Available Sets

EC-45-multi-2 




EC-45-multi-3




EC-45-multi-5

Kit without pH electrode and cell, with cable S7/BNC, temp. probe NT55, pH buffer solution pH 7 and pH 4, conductivity solution 1413 µS and 12,88 mS, DHS-function, Keypad and accessories, with magnetic stirrer


Kit included pH electrode XS STANDARD S7, 1 mt cable S7/BNC, cell glass VPT 80/1 with ATC, DHS-function, pH buffer solution pH 7 and pH 4, standard conductivity solution 1413 µS and  12,88mS, keypad and accessories, with magnetic stirrer 


Kit included pH electrode XS STANDARD-DHS S7, 1 mt cable S7/BNC, cell glass VPT 80/1 with ATC, DHS-function, pH buffer solution pH 7 and pH 4, standard conductivity solution 1413 µS and 12,88mS, keypad and accessories,

with magnetic stirrer

Tester EC-15

with replaceable sensor

EC-15 multi 

• automatic calibration function incl. stability icon 

• 3-color backlit LCD-display 

  (Measurement – Calibration – Alarm)

• pH-electrodes and conductivity cells also 

  available with cable 

• IP 67 waterproof 

• easy replaceable sensor 

• 2 x 1,5 V AAA Batteries, Display of battery level 

EC-15pH pH/mV/°C


• Measuring range: -2 …16 pH, Resolution: 0.01 pH 

• 1 … 3 points calibration 



EC-15pH Food pH/mV/°C


• Measuring range: -2 … 16 pH, Resolution 0.01 pH

• 1 … 3 points calibration

• with replaceable spear pH electrode




EC-15-COND Cond/TDS/Salinity/°C


• Cond scale: 0 … 200 µS - 0 … 2,000 µS - 0 … 20 mS

• 1 … 3 points calibration



EC-15-Multi pH/mV/ Cond/TDS/Salinity/°C


• Measuring range: -2 … 16 pH, Resolution 0.01 pH

• 1 … 3 points calibration 

• COND scale: 0 … 200 µS - 0 … 2,000 µS - 0 … 20 mS

• 1 … 3 points calibration 

Technical data


pH Meas. range

pH resolution

Calibration points 

Electrode condition alarm

Stability meas. indication

mV meas. range

mV resolution

Cond meas. range

Cond accuracy

Calibration points

TDS meas. range

TDS relative accuracy

Temperature range

Resolution

Dimension (Ø x L)


Weight

EC-15 pH/Food*


-2 … 16

0.01

1 … 3

yes

yes

± 1,000

0.1 / 1






0 … 50 °C

0.1 °C

35 x 175 mm

35 x 210 mm*

130 g

EC-15 Cond





yes

yes



0-200 µs; 0-2.000 µS, 0-20 mS

Automatic scale

1 … 3

0.1 ppm … 10 ppt

± 1% full scale

0 … 50 °C

0.1 °C

35 x 175 mm


130 g

EC-15 multi


-2 … 16

0.01

1 … 3

yes

yes

± 1,000

0.1 / 1

0-200 µs; 0-2,000 µS; 0-20 mS

Automatic scale

1 … 3

0.1 ppm … 10 ppt

± 1% full scale

0 … 50 °C

0.1 °C

35 x 175 mm


130 g


Available Sets

EC-15-pH eco


EC-15-pH /pH Food



EC-15-Cond eco



EC-15-Cond


EC-15-Multi

Tester, 1 extra cap, batteries


Tester, 1 extra cap, pH 7 and pH 4 buffer solution, storage solution, neck strap, paper towel, 2x 1,5V AAA batteries, box


Tester, 1 extra cap, batteries


Tester, 1 extra cap, 1413µS and 12,88mS cond. standard solution, neck strap, paper towel, 2x 1,5V AAA batteries, box


Tester, 1 extra cap, pH 7 and pH 4 buffer solution, storage solution, 1413µS cond. standard solution, neck strap,

paper towel, 2x 1,5V AAA batteries, box

Tester EC-10

EC-10 pH 

EC-10 Cond 

• Large LCD display

• IP 67 waterproof protection

• Buffers used for calibration indication

• Measurement stability indicator

• Automatic temperature compensation

• 2 x 1.5 V AAA batteries for long working time

Available Sets

EC-10-pH


Tester, 1 extra cap, pH 7 and pH 4 buffer solution, storage solution,

neck strap, paper towel, 4 x 1.5 V AAA batteries, carrying case.


EC-10-Cond


Tester, 1 extra cap, 1x 55 ml 1413 µS and 12.88 mS cond. standard solution,

neck strap, paper towel, 4 x 1.5 V AAA batteries, carrying case.



EC-10-pH-Eco


Tester, 1 extra cap, batteries


EC-10-Cond-Eco


Tester, 1 extra cap, batteries



Warranty


Instrument: 1 Year

Sensor: 6 Month

Technical data


pH Meas. range

pH resolution

Calibration points

Buffer recognition 

Electrode condition alarm

Cond mes. range 

Cond resolution

Calibration points cond

Cal. standard recocnition 

TDS meas. range

TDS relative accuracy

Auto off 

Dimension ø x L

Weight


EC-10pH


 0 … 14 pH

0.1

1 … 2

3 USA buffer

yes

-

-

-

-

-

-

after 8 minutes

35 x 175 mm

 120 g

EC-10 Cond


-

-

-

-

yes

0-2.000 µS, 0-20 mS

automatic scale

1 … 2

1,413 µS, 12.88 mS

 0.1 ppm … 10 ppt

 ± 1% full scale

after 8 minutes

35 x 175 mm

 120 g

800033

800133

800233


800043

800143

800243


800073

800173

800273


800063

800163

800263


pH Buffer Solutions

Buffer pH4, ± 0.01 / 25 °C, 250 ml bottle, red  

Buffer pH4, ± 0.01 / 25 °C, 500 ml bottle, red  

Buffer pH4, ± 0.01 / 25 °C, 5 Liter red


Buffer pH7, ± 0.01 / 25 °C, 250 ml bottle, green 

Buffer pH7, ± 0.01 / 25 °C, 500 ml bottle, green

Buffer pH7, ± 0.01 / 25 °C, 5 Liter green


Buffer pH9,21,  ± 0.02 / 25 °C, 250 ml bottle, blue

Buffer pH9,21,  ± 0.02 / 25 °C, 500 ml bottle, blue

Buffer pH9,21,  ± 0.02 / 25 °C, 5 Liter blue


Buffer pH10, ± 0.02 / 25 °C, 250 ml bottle, clear

Buffer pH10, ± 0.02 / 25 °C, 500 ml bottle, clear

Buffer pH10, ± 0.02 / 25 °C, 5 Liter clear


pH Storage Solutions

1008013

3M KCl-solution, 500 ml

DAKKS  certified buffer solutions 

are available as well

800613

800633

800643


850513

850313

850303

Conductivity-Standards

Conductivity standard 84 µS/cm ± 1% / 25 °C, 500 ml bottle

Conductivity standard 1,413 µS/cm ± 1% / 25 °C, 500 ml bottle

Conductivity standard 12,880 µS/cm ± 1% / 25 °C, 500 ml bottle


Conductivity-Standard 5 µS/cm ± 0.1 / 25 °C, 300 ml bottle with N.I.S.T Certificate

Conductivity-Standard 5 µS/cm ± 0.1 / 25 °C, 300 ml bottle with DFM Certificate

Conductivity-Standard 1.3 µS/cm ± 0. / 25 °C, 300 ml bottle with DFM Certificate

Redox Buffer

800303

800313

800323

250 ml Redox/ORP 200 mV ± 5mV / 25 °C

250 ml Redox/ORP 475 mV ± 5mV / 25 °C

500 ml Redox/ORP 475 mV ± 5mV / 25 °C

Electrodes

pH - Standard Electrodes

1000203

1000223

1000443


1000363

1000423

1000433

1000263

1000273

1000473

1000463


1000493

1000503

1000513


1002002

1002042

1000413

1000373

1000383

1000213

1000253


1005223

1000393


1000333

Gel

Polymer

Polymer Tip


Standard

Standard HA

Standard HF

STANDARD BNC

STANDARD DIN

STANDARD T - BNC

STANDARD T DIN


Polymer Plast

Polymer Plast BNC

Polymer Plast DIN


201T

201 T DIN

Flat

Flow

Semi-Micro

Micro

Micro P


GEL Plast BNC

FOOD


2 PORE

pH-electrode, gel-filled with ceramic diaphragma

pH-electrode,polymer-filled with open pore diaphragma

pH-electrode,polymer-filled with double open pore diaphragma


pH standard electrode with ceramic diaphragma 

like standard, minimal Alkali error 

like standard, for samples with HF 

like standard, with fix cable BNC

like standard, with fix cable DIN

like standard, with fix cable BNC and Temperature sensor

like standard, with fix cable DIN and Temperature sensor


Polymer electrode with 1 ceramic and 1 x open pore diaphragma, epoxy body

like Polymer, with fix cable BNC

like Polymer, with fix cable DIN


pH-electrode with epoxy body, temperature sensor and fix cable BNC  

pH-electrode with Temperature sensor and fix DIN-cable

pH-electrode for surface measurements, 3-hole diaphragma with Teflon 

pH-electrode for viscous samples and low ion media, Teflon sleeve diaphragma

pH-electrode for test tube measurements

pH-electrode for small volume samples 

pH-electrode for small volume samples with protein, Electrolyte Glycerin


pH-electrode with epoxy body, fix BNC-cable and double diaphragma

pH-electrode with Glycerin KCI electrolyte and 3 ceramic diaphragm


pH-electrode with 2 open pore diaphragma 


More pH-Elektrodes on request

DHS pH - Standard Electrodes

1100103

1100123


1100113

201T DHS

STANDARD T - 

BNC DHS

2 Pore T DHS

pH-electrode with epoxy body, temperature sensor and fix cable BNC, DHS-function 

pH standard electrode with ceramic diaphragma, fix BNC-cable and Temperature sensor, DHS-function

pH-electrode with 2 open pore diaphragma, Temperature sensor and fix 

BNC-cable, DHS-function

2000233

2000663

2000673

Standard ORP

Plast ORP

Plast ORP/BNC

electrode with platinum ring for ORP/Redox

electrode with platinum pin for ORP/Redox

electrode with platinum pin for ORP/Redox, 

fix cable BNC

Conductivity Cells

Electrodes for ORP Measurement

3004062

3003352

3004012

3004072

3004002

3003362

VP8

VPT 80/1

VPT51/01

VPT 80/10

2301T

EPT 4


conductivity cell, cell constant c=1, fix cable BNC

conductivity cell, cell constant c=1, fix cable BNC, temperature sensor 

conductivity cell, cell constant c=0,1, fix cable BNC, temperature sensor for ultrapure water  

conductivity cell, cell constant c=10, fix cable BNC, temperature sensor for sea water

conductivity cell, cell constant c=1, fix cable BNC, temperature sensor   

conductivity cell, cell constant c=0,55, fix Multi-Pin cablel, T-Sensor

4-pole conductivity cell, 0.1 μS…1 S, Only for EC-45-cond


1001733

1001743


1002012

1000112


1001502

Cable S7 / BNC 1 Meter

Cable S7 / DIN 1 Meter


Temperature sensor NT55

Electrode holder


Printer for EC-36 and EC-45

 Printer 1001502

More Accessories

Phoenix Instrument GmbH

Tel.: +49 5131 / 90 818 -30 • Fax: +49 5131 / 90 818 -39

Heinkelstraße 4 • D-30827 Garbsen, Germany